APS Logo

Update on multi-megabar shockless compression at Sandia’s Z machine (2021)

ORAL

Abstract

Quasi-isentropic, shockless ramp-wave experiments promise accurate equation-of-state (EOS) data of materials in the solid phase at relatively low temperatures and multi-megabar (100’s GPa) pressures. In this range of pressure, isothermal diamond-anvil techniques have limited pressure accuracy due to reliance on theoretical EOS of calibration standards, thus accurate quasi-isentropic compression data would help immensely in constraining EOS models. Multi-megabar shockless compression experiments using the Z Machine at Sandia as a magnetic drive with stripline targets have been performed on many solid materials over the past decade. An update is given on recent results and developments, including analysis methods and uncertainty quantification.

Presenters

  • Jean-Paul Davis

    Sandia National Laboratories

Authors

  • Jean-Paul Davis

    Sandia National Laboratories

  • Justin Brown

    Sandia, Sandia National Laboratories