The Thickness And Stretch Dependence Of The Electrical Breakdown Strength Of An Acrylic Dielectric Elastomer

POSTER

Abstract

The performance of dielectric elastomer actuators is limited by electrical breakdown. Attempts to measure this are confounded by the voltage-induced thinning of the elastomer. A test configuration is introduced that avoids this problem: A thin sheet of elastomer is stretched, crossed-wire electrodes attached, and then embedded in a stiff polymer. The applied electric field at breakdown $E_{B} \,$ is found to depend on both the deformed thickness, $h$, and the stretch applied, $\lambda $. For the acrylic elastomer investigated, the breakdown field scales as $E_{B} \;=\;51\,\,h^{\,-\,0.25}\,\,\lambda^{\,0.63}$. The test configuration allows multiple individual tests to be made on the same sheet of elastomer.

Authors

  • Jiangshui Huang

    Harvard University

  • Zhigang Suo

    School of Engineering and Applied Sciences, Harvard University, Harvard University

  • David Clarke

    School of Engineering and Applied Sciences, Harvard University, Harvard University