Study of DC and impulse discharges at sub-micrometer gap distances in various gases
ORAL
Abstract
Using a point to plane electrode system and high precision positioning system, gap distances down to 100 nm are obtained. An hermetic enclosure allows to control the gas nature and pressure during breakdown experiments. A 1~mA current criterion is used to determine the breakdown voltage. Discharges can occur in various gases below 300 V in sub-micrometer gaps. This study enables to compare breakdown voltage under DC and impulse discharges, versus pressure and distance in various gases (dry air, N2, Ar, He). Time delay to breakdown are also obtained under fast impulse. At the shortest gaps, breakdown discharges occur at voltage lower than 100V, strongly departing from the Paschen curve. Results are discussed in terms of classical gas discharge mechanisms, modified by Fowler-Nordheim electron emission.
–
Authors
-
Nathan Ngouoto
Univ. Grenoble - Alpes, CNRS, Grenoble INP, G2Elab, F-38000
-
Olivier Lesaint
Univ. Grenoble - Alpes, CNRS, Grenoble INP, G2Elab, F-38000
-
Nelly Bonifaci
Univ. Grenoble - Alpes, CNRS, Grenoble INP, G2Elab, F-38000
-
Olivier Gallot-Lavallee
Univ. Grenoble - Alpes, CNRS, Grenoble INP, G2Elab, F-38000
-
Nawres Sridi-Convers
Safran Electronics & Defense
-
Christophe Poulain
CEA LETI