ITER ECE in Situ Prototype Calibration Source and its Integration into the ITER ECE Diagnostic

POSTER

Abstract

A critical component in the ITER ECE diagnostic is an in situ calibration source. The US and India are developing the diagnostic with the US leading in development of the calibration source. The source is a large area (200mm diameter) emitter. It will generate blackbody emission (emissivity $>$ 0.7) for frequencies greater than 120 GHz in the ITER primary vacuum (VQC 1B). The source will operate at temperatures up to 800 \r{ }C for calibration runs during maintenance periods. A prototype source has been designed, constructed and tested in vacuum conditions. Results of these tests will be presented, along with a progress report on its integration into the ITER ECE system. Additional challenges of real-world application to J-TEXT and EAST will be presented.

Authors

  • P.E. Phillips

    Fusion Research Center, The Univ. of Texas at Austin

  • M.E. Austin

    Fusion Research Center, The Univ. of Texas at Austin

  • W.L. Rowan

    University of Texas, FRC UT, The University of Texas at Austin, FRC-UT Austin, Fusion Research Center, The Univ. of Texas at Austin

  • J. Beno

    University of Texas, CEM-UTA

  • A. Ouroua

    CEM-UTA

  • R.F. Ellis

    University of Maryland, Univ. of MD

  • H.K.B. Pandya

    ITER-India, IPR, A-29, GIDC Electronic, Estate, Sec.25, Gandhinagar-380025 India