Abstract

Calibrated r-$\theta $ ion density profiles from wire-array and cylindrical foil experiments on the 1-MA COBRA machine will be presented. Profiles are axially averaged over the 1-cm height of the array. The data was gathered using an axial X pinch backlighter.\footnote{I.C. Blesener et al., ``Axial x-ray backlighting of wire-array Z-pinches using X pinches'', Rev. Sci. Instrum. 80, 123505 (2009).} Images have better than 5-micron resolution with calibrated ion densities from 10$^{18}$ to 10$^{20}$ cm$^{-3}$. The latest data will be presented, comparing the timing and development of ablation streams and precursor formation between wire-arrays and cylindrical foils. Experimental data will also be compared to simulation results.

Authors

  • Isaac Blesener

    Cornell University - LPS

  • John Greenly

    Cornell University, Cornell University - LPS, Cornell University, Laboratory of Plasma Studies

  • Sergei Pikuz

    Cornell University, Cornell University - LPS, Cornell University, Laboratory of Plasma Studies

  • Tania Shelkovenko

    Cornell University - LPS, Cornell University, Cornell University, Laboratory of Plasma Studies

  • Bruce Kusse

    Laboratory of Plasma Studies, Cornell University, Cornell University - LPS

  • Charles Seyler

    Cornell University, Cornell University - LPS