Real-time sensing and gas jet mitigation of VDEs on Alcator C-Mod
POSTER
Abstract
Experiments have been carried out in Alcator C-Mod to test the effectiveness of gas jet disruption mitigation of VDEs with real-time detection and triggering by the C-Mod digital plasma control system (DPCS). The DPCS continuously computes the error in the plasma vertical position from the magnetics diagnostics. When this error exceeds an adjustable preset value, the DPCS triggers the gas jet valve (with a negligible latency time). The high-pressure gas (argon) only takes a few milliseconds to enter the vacuum chamber and begin affecting the plasma, but this is comparable to the VDE timescale on C-Mod. Nevertheless, gas jet injection reduced the halo current, increased the radiated power fraction, and reduced the heating of the divertor compared to unmitigated disruptions, but not quite as well as in earlier mitigation experiments with vertically stable plasmas. Presumably a faster overall response time would be beneficial, and several ways to achieve this will also be discussed.
Authors
-
R.S. Granetz
Massachusetts Institute of Technology, MIT
-
S.M. Wolfe
-
V.A. Izzo
MIT PSFC
-
M.L. Reinke
-
J.L. Terry
Plasma Science and Fusion Center, MIT, MIT PSFC, MIT-PSFC
-
J.W. Hughes
-
K. Zhurovich
Massachusetts Institute of Technology, MIT Plasma Science and Fusion Center
-
D.G. Whyte
-
M. Bakhtiari
U. of Wisconsin, Dept of Engineering Physics, UW-Madison, Univ. of Wisconsin, Madison
-
G.A. Wurden
Los Alamos National Lab, (LANL)