Transmission Profiles of a Mini-Orange Spectrometer for Conversion-Electron Spectroscopy
POSTER
Abstract
A Mini-Orange Spectrometer (MOS) consists of an orange-type array of 3, 4, or 6 permanent magnets that focus electrons onto a cooled Si-Li detector. At the center of the array is a lead plug for shielding gamma rays and delta electrons. Since electron transmission of an MOS is highly energy dependent - electrons with too much or too little energy are not bent into the detector - measuring transmission as a function of electron energy is an important callibration task, allowing the MOS to make absolute intensity measurements for conversion electron lines. We report a method for calculating the absolute transmission for an MOS using standard calibration sources, as well as discuss the relevance of conversion electron spectroscopy to the study of nuclear structure.
Authors
-
Axel Schmidt
Yale University
-
Roman Gernhaeuser
Technische Universitaet Muenchen
-
Reiner Kruecken
TU Muenchen, Germany, Technische Universitaet Muenchen
-
Robert Muenzer
Technische Universitaet Muenchen