APS Logo

Lubrication model of a valve-controlled, gravity-driven bioreactor

ORAL

Abstract

Hospitals sometimes experience shortages of donor blood platelet supplies, motivating research into in vitro production of platelets. We model a novel platelet bioreactor described in Shepherd et al. [1]. The bioreactor consists of an upper channel, a lower channel, and a cell-seeded porous collagen scaffold situated between the two. Flow is driven by gravity, and controlled by valves on the four inlets and outlets. The bioreactor is long relative to its width, a feature which we exploit to derive a lubrication reduction of Navier-Stokes flow coupled to Darcy. Models for two cases are considered: small amplitude valve oscillations, and order one amplitude valve oscillations. The former model is a systematic reduction; the latter incorporates a phenomenological approximation for the cross-sectional flow profile. As the shear stress experienced by cells influences platelet production, we use our model to quantify the effect of valve dynamics on shear stress.

 

1: Shepherd, J.H., Howard, D., Waller, A.K., Foster, H.R., Mueller, A., Moreau, T., Evans, A.L., Arumugam, M., Chalon, G.B., Vriend, E. and Davidenko, N., Biomaterials, 182, pp.135-144. (2018)

Presenters

  • Helen Saville

    University of Oxford

Authors

  • Helen Saville

    University of Oxford

  • Sarah L Waters

    University of Oxford

  • James M Oliver

    University of Oxford

  • Daniel Howard

    University of Cambridge

  • Ruth Cameron

    University of Cambridge

  • Cedric Ghevaert

    University of Cambridge

  • Serena Best

    University of Cambridge