APS Logo

Performance of kHz-rate plenoptic-PIV versus tomo-PIV on a 10mm-scale pipe flow

POSTER

Abstract

Plenoptic-Particle Image Velocimetry (PIV) is a 3D velocimetry technique performed via custom cameras imbued with microlens arrays (MLA). The MLA serves to encode both spatial and parallax information of a subject into a single recorded image, allowing depth inference using as few as one plenoptic camera. Thus, plenoptic-PIV represents a viable solution for 3D velocimetry in facilities with limited optical access, while also reducing alignment complexities and hardware costs relative to multi-camera tomographic-PIV. Here, we show the performance comparison of a single-camera high-speed plenoptic-PIV against the 4-camera tomographic-PIV, to characterize 3D flow in a 10mm scale pipe. The flow was varied from steady laminar (Re$_{\mathrm{d}}=$621-1167) to turbulent (Re$_{\mathrm{d}}=$3283) to pulsatile ($\omega_{\mathrm{0}}=$9.5) to produce different velocity profiles. Results, after 3D reconstructions and cross-correlations, were benchmarked using metrics such as particle counts, mutual information between correlating frames, and reconstructed particle shape. The velocity-field probability density function and the average velocity profiles were compared relative to each other and to the expected profile from pipe-flow theory. ~

Authors

  • Bibek Sapkota

    Auburn University

  • Sayantan Bhattacharya

    Purdue University

  • Zu Puayen Tan

    Auburn University

  • Dustin Kelly

    Auburn University

  • Javad Eshraghi

    Purdue University

  • Pavlos Vlachos

    Purdue University

  • Brian Thurow

    Auburn University