Fully developed pipe and triangular channel flow measurement using Magnetic Resonance Velocimetry
ORAL
Abstract
Magnetic resonance velocimetry (MRV) is a non-intrusive flow visualization method which is able to measure the 3 dimensional 3 component (3D3C) mean velocity field in complex geometries, using a healthcare MRI scanner. Since this technique is based on nuclear magnetic resonance (NMR), it is free from optical distortion and does not require tracer particles. Due to these powerful advantages, MRV usage is gradually expanding from biomedical fields to the engineering domain. In this study, we validate the performance of MRV by measuring fully developed pipe flow and compare measured data with time averaged DNS data. We then investigate the overall flow characteristics in a triangular channel with a sharp corner. At the sharp corner, boundary layer effects dominate and the effect of turbulence is reduced. This information has implications for engineering applications such as flow in a turbine blade internal cooling passage at the sharp trailing edge.
–
Authors
-
Seungchan Baek
Seoul national University
-
Wontae Hwang
Department of Mechanical & Aerospace Engineering Seoul National University, Seoul national University