Fluid dynamic modelling of renal pelvic pressure during endoscopic stone removal
ORAL
Abstract
Endoscopic kidney stone removal procedures are known to increase internal pressure in the renal pelvis, the kidney’s urinary collecting system. High renal pelvic pressure incites systemic absorption of irrigation fluid, which can increase the risk of postoperative fever and sepsis or the unwanted absorption of electrolytes. Urologists choose the appropriate surgical procedure based on patient history and kidney stone size. However, no study has been conducted to compare the pressure profiles of each procedure, nor is there a precise sense of how the renal pelvic pressure scales with various operational parameters. Here we develop physical models for the flow rates and renal pelvic pressure for various procedures. We show that the results of our models are consistent with existing urological data on each procedure and that the models can predict pressure profiles where data is unavailable.
–
Authors
-
Alexandros Oratis
Boston University
-
John Subasic
Boston University
-
James Bird
Boston University
-
Brian Eisner
Massachusetts General Hospital Harvard Medical School